Biography
Interests
Ana Paula Gebert de Oliveira Franco1*, Renata Tomazini de Queiroz2, Márcio José Fraxino Bindo3, Nerildo Luiz Ulbrich3, Osnara Maria Mongruel Gomes4 & Rui Fernando Mazur5
1PhD in Dentistry, Pontifice University Catholic of Paraná, Curitiba, Paraná, Brazil
2Student of Dentistry, Pontifice University Catholic of Paraná, Curitiba, Paraná, Brazil
3Professor of Dentistry, Federal University of Paraná, Curitiba, Paraná, Brazil
4Professor of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
5PhD in Restorative Dentistry, Paulist State University Júlio Mesquita Filho, São Paulo, São Paulo, Brazil
*Correspondence to: Dr. Ana Paula Gebert de Oliveira Franco, PhD in Dentistry, Pontifice University Catholic of Paraná, Curitiba, Paraná, Brazil.
Copyright © 2019 Dr. Ana Paula Gebert de Oliveira Franco, et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
The properties of resin cements used to lute prosthesis to dental structures should be investigated
by simulating the oral environment.
The aim of this study was to evaluate the mechanical properties of resin cements of chemical and
dual sets by immediate hardness and after accelerated aging by thermocycling.
Five Disc shaped specimens were prepared for each resin cement evaluated using a metallic mold
(10mm diameter X 1mm thick). The resin cements evaluated in the present study were: Multilink
(Ivoclar-Vivadent), Relyx ARC (3M/ESPE), All Cem (FGM), Enforce (Caulk/Dentsply), Variolink
II (Ivoclar-Vivadent), and Relyx U-200 (3M/ESPE). The specimens were subjected to indentations
before and after accelerated aging by thermocycling to determine mechanical properties such as
hardness and elastic modulus.
Statistical analysis revealed significant differences in hardness and elastic modulus between the
moments (before and after accelerated aging). Multilink presented the lowest elastic modulus and
hardness (8.51GPa before aging, 8.31GPa after aging, and 0.33 before aging, 0.32 after aging) and
Relyx U-200 presented high elastic modulus and hardness (11.61GPa before aging, 12.84GPa after
aging, and 0.53 before aging, 0.66 after aging), respectively.
Water induce to hydrolysis and degradation on resin cements, which in association with the
temperature variations can cause alterations in materials properties.
Introduction
The indirect restorations (crowns, laminated, inlays, onlays, and fixed prosthesis) and and root posts are
often present in the daily routine of clinicians [1,2]. The patient’s expectations for dental rehabilitations that
mimics the natural dentition accelerated the aesthetic dental materials evolution and resulted in the need for
the development of resin cements to lute prosthesis to dental structure. According to the curing mode, three
possible alternatives can be chosen: chemical, photo or dual-curing resin cements. The use of auto-cured
resin cements offers chemical cure with luting of base and catalyst pastes, worse handling characteristics
due to the absence of control of the setting reaction. Photoactivated allow setting control greater than
chemical cements. Dual-curing resin cements are expected to combine favorable properties of both, auto
and photoactivated systems [3]. Regarding resin cements, the curing mode can also influence of shrinkage
produced after polymerization. The shrinkage is dependent to unfavorable factor of cavity configuration
(factor-C). The high factor-C can restrict the flow of resin cement affecting the integrity of the adhesive
interface [1].
Adequate polymerization is a crucial factor for obtaining optimal mechanical properties and satisfactory clinical performance of dental resin material like Young's modulus and hardness [4]. Good mechanical properties, high degree of conversion and high cross-linking density may be advantageous not only from the point of view of certain mechanical properties, but also because of reduced susceptibility to the softening action of food substances and to enzymatic attack [5].
Water degradation is a phenomenon that can cause several alterations in dental resins, from physical changes, such as plasticization and softening to chemical ones like oxidation or hydrolysis [6]. Negative effects in the physical properties (tensile and flexural strength, Young’s modulus, wear resistance) of the composite materials caused by water exposure have been reported by Sorderholm et al. [7]; Oysaed et al. [8]; Scarret et al. [9], respectively.
The cementation procedure is necessary to clinical success of the prosthesis because it provides the interface sealing and reduction of marginal infiltration, avoiding pulp sensitivity and caries [2,4].
Recently, the photoactivated have been used less than auto-cured and dual-cured resin cements because the visible light doesn't get act effectiveness in deep regions or over thick prosthetic devices [10].
Choose of a cementation agent is dependent of clinical condition combining with physical, biological and handling properties [11].
One of the most advantage of nanoindentation is the possibility of testing the cements in situ [3], this method has been applied in dentistry because of less material is needed to produce specimens in reduced dimensions and it’s possible to obtain faithful results.
The aim of this study was to evaluate the mechanical properties of resin cements chemically and dual cured by nanoindentation test done immediately and after accelerated aging.
Materials and Methods
The resin cement evaluated in the present study were Multilink (Ivoclar-Vivadent Schaan, Liechenstein)
(M), Relyx ARC (3M/ESPE, St. Paul, MN, USA) (ARC), All Cem (FGM, Joinville, SC, BR) (AC), Enforce
(Caulk/Dentsply, Milford, DE, USA) (EN), Variolink II (Ivoclar-Vivadent Schaan, Liechenstein)
(VR) and Relyx U-200 (3M/ESPE, St. Paul, MN, USA) (U-200). The resin cements were manipulated
according the manufacturer instructions (Table 1).
Five-disc shaped specimens were prepared for each resin cement evaluated using a metallic mold, 10mm in diameter and 1mm thick. The molds were placed on a glass plate and the materials were inserted into the molds with Hu-Friedy instrument. After insertion, the mold was covered with a polyester strip and a glass microscope slide.
The Multilink resin cement was allowed to auto-cure for 5 min, while the dual resin cements mixture was photoactivated with an Optilux 500 device (Demetron/ Kerr, Danbury, CT, USA) with a light output not less than 600mW/cm2 for 40s.
After 10 min, specimens were removed from the molds and stored in darkness and distilled water until evaluation at 37ºC for 24 h. Samples were luted on a metallic supports and surfaces were polished with alum in a suspension slurry of 1μm and felt metallographic discs of 1μm for 2 min each.
Nine indentations were made on the disc shaped specimens. Young's modulus and hardness of the cements were determined from the load-displacement curves. The indentations were made with Berkovich point, 400mN (40gf) greatest load, peak hold time of 30 seconds and time to load of 5s.
Specimens were subjected to thermocycling in water (500 X, 5ºC/55ºC dwell time of 15 seconds) to simulate aging condition. Subsequently, the specimens were evaluated again according described before.
To compare nanohardness values and Young's modulus before and after aging accelerated was used Kolmogorov-Smirnov test, ANOVA repeated measures and Tukey's test in SPSS software.
Results
The Komolgorov-Smirnov revealed symmetric amounts distribution. The descriptive analysis is present in
Table 2. ANOVA repeated measures to analysis of Young's modulus showed significant differences between
resin cements, between moments (before and after accelerated aging) and revealed interactions between
moment-cement. Tukey HSD test was used to multiple comparisons and showed significant differences in
Young's modulus between AC and ARC, AC and M, AC and U-200, ARC and EN, ARC and M, ARC
and U-200, ARC and VR, EN and M, EN and U-200, M and U-200, M and VR, VR and U-200 resin
cements. Tukey HSD test revealed significant differences between moments before and after accelerated
aging (p<0.05). ANOVA repeated measures to hardness analysis showed significant differences between
resin cements and revealed interactions between moment-cement, but no significant differences were
obtained between moments. Tukey HSD test showed significant differences in hardness between ARC and
AC, AC and M, ARC and M, ARC and U-200, EN and M, EN and U-200, M and U-200, M and VR,
U-200 and VR resin cements. M presented the lowest elastic modulus and hardness (8.51GPa before aging,
8.31GPa after aging and 0.33 before aging, 0.32 after aging), respectively. U-200 presented high Young's
modulus and hardness (11.61GPa before aging, 12.84GPa after aging and 0.53 before aging, 0.66 after
aging), respectively.
*Different capital letters reveal significant differences in the line for each property (hardness and elastic modulus). Different small letters reveal significant differences in the column.
Discussion
This study agrees with Ceballos et al. [3] results. The chemically cured resin cement (Multilink), presented
the lowest values of stiffness and hardness, although is ability to being deformed without damage is superior
to other cements, but disagrees with Hofmann et al. [12], where properties of self-curing resin cement
ranged between those of the dual-cure materials.
Dual resin cements seem to possess the best combination of properties. The dual resin cements presented intermediate values and self-adhesive resin cement Relyx U-200 revealed high stiffness and hardness values in accordance with other studies [2]. Moosavi et al. [13] studied a dual self-adhesive resin cement (Clearfil SA cement) and showed hardness values ranging from 0.43 to 0.51. Attar, Tam and McComb [11] studying mechanical and physical properties of dental luting agents such as zinc phosphate cement, glass ionomer, resin-modified glass ionomer, resin cements of dual and chemical sets, obtained in flexural test that de zinc phosphate presented highest Young's modulus which has contributed to its clinical success for many years. The low Young's modulus for resin-modified glass ionomer suggested that these materials should be limited for use to low stress and single prosthetic units. They related that resin luting agents displayed a good combination of high flexural strength and high Young's modulus. The good mechanical properties, coupled with adhesive capabilities, make the use of resin cements an excellent choice for difficult retention situations. When they tested the storage for 24 h and 3 months, they found no significant differences in modulus of elasticity for zinc phosphate and resin cements groups, there was an increase in modulus of elasticity for both conventional and the resin-modified glass ionomer groups. These results disagree to the present study that obtained significant differences between immediate and thermocycled specimens (p < 0.05), maybe because the immersion in different temperatures (5 and 55ºC) that can affect hardness of the materials. Irie et al. [14] related that the thermal stress increased flexural strength and Young's modulus for all luting materials (Compolute, Permacem, Fuji Plus and Panavia 21). This study showed that the properties increased to U-200 and EN, but to other resin cements the properties decreased after termocycling. Water that has entered the polymer by sorption can hydrolyze the covalent bonds in the resin matrix, filler-matrix interface, or filler. The hydrolysis can cause loss of mass, filler debonding and degradation of mechanical properties such hardness and Young's modulus [2].
The properties of resin cements are influenced by the nature of the matrix, type of filler, filler volume, fillermatrix interfacial bond, filler load and polymerization mode [2].
Surface hardness of materials characterizes their outer surface properties and is important to determine their capacity to be polished and their abrasive wear rate [15].
Dental materials that have properties similar to dental structures have good behavior [2,16-20]. All resin cements presented Young's modulus closer than dentine (17,5 ± 3,8 GPa), according Plotino et al. [21], but self-adhesive resin cement was more similar than the other resin cements.
The in vitro nature of the present study is considered a limitation. Future studies should focus on clinical research.
Conclusion
Considering the limits of this study, the following conclusions can be formulated.
Significant differences in hardness and elastic modulus between moments (before and after thermocycling) were found.
The resin cement of chemical set Multilink presented the lowest elastic modulus and hardness.
The dual self-adhesive resin cement Relyx U-200 presented high elastic modulus and hardness.
Water induce to hydrolysis and degradation on resin cements, which in association with the temperature variations can cause alterations in materials properties.
Acknowledgements
The authors would like to thank Federal University of Parana for their equipment of indentation and
manufacturers for material support.
Conflicts of Interest
The authors declare no conflict of interest, financial or otherwise.
Bibliography